The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. The circuit is protected by two ganged breakers. Help! A switch is easier to use, so you dont have to open the clock and stick wet fingers in there, and using the breaker is also less than desirable, as they can wear out faster if used as a switch. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. It should sit down nicely. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. Hi, hope you are doing well. First, secure the green ground wire to the green ground screw, then connect the other two wires to terminals #1 and #3. Same way, WD-40 or any light lubricating oil. Any advice on how to fix. "height": "219",
Look for any disconnected or damaged wires leading to the motor on the rear of the clock. If you cant see an issue with the gears, then it could be the timer motor. The most common pool timer used for inground pool pumps is the Intermatic time clock. Replaced complete new timer assuming 5 years perfect service probably wore it out. You should be able to see the gears moving. It is a good idea to use pliers or a wrench and reseat the trippers, then tighten them at the desired on/off times. Hello. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. "name": "In The Swim",
I just replaced an Intermatic WG1573-10D timer motor. Line is incoming, Load goes to the pump. The other gears are not and the pump will not turn on or off unless done manually. Replace a new T104. we purchased the house 5 years ago so not sure how old the timer is? My pool pump and skimmer are on two different motors. The back of the timer dog has a tab that flips the switch, check the alignment of both, the dog may not be contacting the switch with enough surface to flip it on? There are many reasons why your pool timer may not be working. Any suggestions on how to troubleshoot? Wired correctly, #10 wire, nothing. Many thanks! Thank you so much. Hi Chad, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well. This will disengage the dial and allow you to spin it in either direction. For Sale: 2 beds, 2 baths 1152 sq. Any ideas why its doing that? Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. Ft. 750 Joshua Dr, Hollister, CA 95023. I dont see any debris blocking the off dog. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. Thanks. Is it Necessary? Pool co says T104 timer needs replacement and filter cartridge. To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. Hi Carlos, is there a GFCI outlet in the circuit? The terminals on the wires aren't tight. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. When the trippers are done up, you shouldnt be able to move them with your hands. how do I check the manual over ride switch to see if it is off? Rich. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? Terminal A (farthest to the left side) is not connected to anything. Everythings OK now, unit works just fine. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. Hi Ryan, that sounds like a bad motor or a broken gear, you can replace just the motor, or the entire clock mechanism. In this article, well cover what problems you may find with your Intermatic timer and how you can fix it without having to run to the store. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. Black goes to _1 If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. Check the motor, and be sure the label is not printed 50 hz. They should be straight, if not, replace them. My intermatic pool timer will not automatically turn on. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. I had to order new trippers as mine have been straightened too many times. Perhaps bad wiring or a bad breaker is to blame. Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). I have a PF1112T. This product is certified by Amazon to work with Alexa. If your Intermatic swimming pool timer has stopped working you will have to do something called troubleshooting. Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. "height": "219",
I am using the breaker to turn on and off the pool pump. 2,767 Sq. However, since I did that the time clock stopped working I looked at the motor visual window and nothing is moving. Take them off and inspect them. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. 120Volt Tork 1101 timers can be fixed with repair parts. The on/off pins are tight and pretty new stillany thoughts? The tripper will not move. (usually not). Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). What is the problem? Any idea what may be causing this? OPEN TODAY, 12PM TO 3PM. The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. Move the switch and see that they separate when off, and come together when on. Deep down, I figured it was something I did wrong and it was. Or may be bent and not come together. I not sure if this is the best timer to use. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Please advise. The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. Started about a month ago and I checked the dog tripper at that time and it started working again for awhile but hasn't now for a week. The rest of your setup is probably fine. Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. You need extreme care in this next step.
If your pool pump timer is beyond repair, call a professional to replace it. Move the start and stop pins to appropriate times for swimming pool filter operation. My pool pump timer is not working properly. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveller reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. Hi Davy, Pool Timer Not Turning ON or OFF!! I had the exact same thing happen recently. Is this broken? Grab it, pull it towards you, move it around then place it back down. Slide it around the pool timer dial to the correct start time and re-tighten it. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. If you pull out on the clock dial, you can turn it to set the current time, aligning with the silver down-arrow, located at 6 oclock. So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. Any other thoughts? I have a Model T104P and have a new green on tripper attached. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. Donna Simpson Eating Website But What Toilet? There are many reasons why your pool timer may not be working. Pools are not cheap! VIDEO TOUR. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. Hi there, DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . The A terminal is not normally used, unless you have a 3 wire service. Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. Dont know what the issue is. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. Is this a bad timer mechanism or loose wire? Hi Bob, you have two blacks and one neutral? Basically youre eliminating possibilities until you find the cause. If you dont think the mechanism is the issue, move onto the next step. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. The trippers can also get damaged. Hello. 4 Beds. You most likely just need to now set the pins and the clock and your timer will work. You dont have two OFF trippers, right? I need to replace a timer for my pool vacuum. The trippers will "trip" the analog clock to turn on and off automatically at the set times. hi, I have a smart pump for my pool, the time clock turns on in the morning and at the same time I see that the pump has power but it doesnt turn on, I have to turn on manually, is it something that the electrician has to connect to the pump so they are synchronized? Hello. Terminals 2 and 4 are used for wires going to the load (pump). Repeat the process for the "on" pin. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. With this model can I control both of these motors with two different on and off times. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. Welcome to Pool Spa Outpost! If after verifying you have power to the timer, then check these things to further troubleshoot. I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. Pool pump timers can last up to 20 years, depending on the model. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 "dateModified": "1/10/2020",
"primaryImageOfPage": {
This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. Monday the clock face was free spinning, today when I got home it had broken and fallen off. (For outside light timer) The one before was original to the house & I had no trouble. Confused. A timer that switches on and off at the wrong times usually occurs after a power outage. I have a 2 speed pump. Check out our online selection of new Intermatic timer clocks at InTheSwim.com! If the pump doesnt come on, follow the steps below. "url": "https://blog.intheswim.com/"
Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. But if the timer doesnt come back on after a storm, there could be an issue. You will first need to adjust the time on the timer first. My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). But the next morning it wont engage by itself again, it seems it sticks when getting to the point its supposed to flip on. the timer was directly plugged into a gfci and the pump directly into the timer. Hi, I got the same problem as my clock not working. Sound right? Close. However, after several hours, maybe overnight, the associated breaker will trip. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. How do you know if your pool timer is bad? any suggestions about how i might avoid another situation like the above would be appreciated. How can it keep time if lever is in off position (manual lever). The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. Im wanting to use T101 to wire my above ground pool pump. Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. I see that the Intermatic WG1573-10D Replacement 208-277 VAC, 60 Hz Motor, is compatible with For use with T102, T104 and WH40 clocks by Intermatic. These clocks determine when your pool pump turns on, and how long it runs. Replace the gears if this is an issue. If the pump comes on, you definitely have power to the timer. Is it keeping time normally? Only perform this step if you are qualified. Sometimes its way quick just to replace it rather than spend hours troubleshooting. Or other advice or explanation. I used to run the pump for 8-9 hrs a day. Now try to jiggle it on and off. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. Any suggestions? GFCI breakers trip at a very low threshold, doesnt take much. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
We cover T101, T103 and T104 models of mechanical pool timers. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . "address": "",
Yes, seen that before! Found the answer. I have a inground pool with T10003RT4 control panel. However, the timer will stop around 10pm everyday and will not continue moving forward again. However, intermittently after the ON tripper switches pump on the pump will stop. Make sure the middle time pointer is tight. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. "@type": "ImageObject",
Why it always stop around 10pm by itself and not moving again? What do you suggest to do to get the cover up and the pillows back into position. Inspect the tripper portion, if it looks rounder or worn, replace them. The position of the metal bar forces the gear next to it to turn one way or another. Is there anything else I can do or do I need to get a new one? If not, that sounds like a weak/bad motor. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. Your email address will not be published. Ive seen it happen from lightning strikes, or insect infestation. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. My pump has a plug. I can turn the pool pump on via the manual power lever thats located at 5 O clock on the timer. Hi. Until it came in, I manually turned on and the tripper turned it off. Things are working fine and all of a sudden the pool pump did not start in the morning. screwfindinganame on June 18, 2013 at 11:36 pm "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
how should I lubricate those? Are the trippers slid all the way onto the dial fully? I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. The timer appears to be working fine (keeps time). Karl, good question. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. No matter what caused the issue, there is typically an easy fix! See the next section in this article for that. Is it Necessary? You will first want to look at the pool timer and see if you have two timer pins. It may or may not reduce the noise level however. 3. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. Sometimes the trippers get loose or damaged. That will do it. "@type": "Organization",
Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. You can find this in your power board. Now Im having to turn my pool pump on and off manually. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. I currently manually turn it on and off. The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. No broken or loose wires visible. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. I have to reset the time every day. I also dont see any ants or other insects. Please let me know if you find the solution! With the power switched off at the breaker, take out the main part of the timer and carefully inspect the gears for obstructions and missing teeth. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. },
Take them off and inspect them and look for twists in them. Hi Larry, if you can see the motor gears turning in the visual motor check, you may just need some lubrication added to the tripper mechanism. Also known as an RCD (residual current device) in Australia and the UK. One morning I noticed my pool didnt automatically turn off. All Rights Reserved. Simply screw it back into place until its snug. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. I unscrewed the clip and put it back on and its still doing the same thing. "keywords": "",
"headline": "Intermatic Pool Timer Troubleshooting",
Timer must be reset for current time after power outage. The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. It started lagging again a week or so ago. Im going to try inspecting the back of the timer to see if a wire go knocked loose or something.
Chamberlin And Associates Portal, D3 Lacrosse Forum, Club Green Meadows Vancouver Membership Fees, Articles P